Mostrar el registro sencillo del ítem

Desarrollo de un medidor autónomo de bajo costo para la determinación de calidad química del agua

dc.contributor.authorBaltuano, Oscar
dc.contributor.authorLa Rosa Toro, Adolfo
dc.contributor.authorCoria, Lucy
dc.contributor.authorCjuno, Américo
dc.contributor.authorSantiago, Julio
dc.contributor.authorMorales, José
dc.contributor.authorHernández, Yuri
dc.contributor.authorMontoya, Eduardo
dc.creatorSantiago, Julio
dc.creatorMontoya, Eduardo
dc.creatorHernández, Yuri
dc.creatorMorales, José
dc.creatorLa Rosa Toro, Adolfo
dc.creatorCjuno, Américo
dc.creatorBaltuano, Oscar
dc.creatorCoria, Lucy
dc.date.accessioned2014-04-25T02:44:26Z
dc.date.available2014-04-25T02:44:26Z
dc.date.issued2014-01
dc.identifier.citationBaltuano O, La Rosa Toro A, Coria L, Cjuno A, Santiago J, Morales J, Hernández Y, et al. Desarrollo de un medidor autónomo de bajo costo para la determinación de calidad química del agua. Informe Científico Tecnológico. 2012; Volumen 12, p. 59-64.es_PE
dc.identifier.urihttps://hdl.handle.net/20.500.13054/131
dc.description.abstractSe presenta detalladamente el desarrollo de un prototipo de medidor autónomo de bajo costo, para la determinación de plomo (II) y otros metales pesados disueltos en agua, así como de pH, conductividad y temperatura. El prototipo incluye un potenciostato, operado de manera autónoma por un micro-controlador, así como un sistema de comunicación mediante tecnología GSM, en la modalidad de mensajes de texto. Se muestran y discuten los resultados experimentales, obtenidos en condiciones de campo, en un puquio del río Lurín. Los resultados indican concentraciones de Pb(II), Cd(II), Cu(II) y Hg(II), por debajo de 5 µg/L, así como pH de 7,3 y conductividad específica de 14 µS/cm. La presente publicación está basada en el informe final del proyecto PROCYT 308 2011 financiado por CONCYTEC.es_PE
dc.description.abstractThe development of a prototype of an autonomous measuring device, for the determination of Pb(II) and other heavy metal ions dissolved in water, as well as of pH, conductivity and temperature. The prototype includes a potentiostat, operated by a microcontroller in an autonomous way, as well as a communication system by GSM technology, in the modality of text messages. Experimental results, obtained under field conditions, in a water eye of the Lurin River, are shown and discussed. The results indicate concentrations below of 5 µg/L, for Pb(II), Cd(II), Cu(II) y Hg(II), as well as a pH value of 7,3 and a conductivity value of 14 µS/cm. This article is based on the final report of the CONCYTEC research contract PROCYT 308 2011.
dc.description.sponsorshipInstituto Peruano de Energía Nuclear
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherLimaes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectMetales pesadoses_PE
dc.subjectInstrumentos de medidaes_PE
dc.subjectControl de calidades_PE
dc.subjectAguaes_PE
dc.titleDesarrollo de un medidor autónomo de bajo costo para la determinación de calidad química del aguaes_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem