Caracterización de una biohidroxiapatita tratada con radiación gamma para aplicaciones biomédicas
dc.contributor.author | Castro, Emma | |
dc.contributor.author | López, Alcides | |
dc.contributor.author | Ramos, Bertha | |
dc.contributor.author | Vargas, Johnny | |
dc.contributor.author | Vivanco, Mónica | |
dc.contributor.author | Olivera, Paula | |
dc.creator | Vivanco, Mónica | |
dc.creator | Olivera, Paula | |
dc.creator | López, Alcides | |
dc.creator | Vargas, Johnny | |
dc.creator | Castro, Emma | |
dc.creator | Ramos, Bertha | |
dc.date.accessioned | 2014-04-25T17:55:28Z | |
dc.date.available | 2014-04-25T17:55:28Z | |
dc.date.issued | 2014-01 | |
dc.identifier.citation | Castro E, López A, Ramos B, Vargas J, Vivanco M, Olivera P. Caracterización de una biohidroxiapatita tratada con radiación gamma para aplicaciones biomédicas. Informe Científico Tecnológico. 2012; Volumen 12, p. 99-106. | es_PE |
dc.identifier.issn | 1684-1662 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13054/137 | |
dc.description.abstract | Debido a su excelente biocompatibilidad, bioactividad y osteoconducción, la hidroxiapatita es un material que se utiliza ampliamente en cirugía ortopédica, traumatología, odontología y cirugía maxilo-facial. El presente trabajo tiene como propósito caracterizar una biohidroxiapatita (BHA) esterilizada por radiación gamma y tratada a las dosis de 0, 25, 50, 100, 200 y 500 kGy, utilizando técnicas gravimétricas, espectroscopía FTIR, difracción de rayos X, fluorescencia de rayos X, microscopía electrónica de barrido y pruebas organolépticas. Se realizaron pruebas dosimétricas para la irradiación del producto y la esterilidad de la BHA se comprobó mediante pruebas microbiológicas. Los resultados de las pruebas de caracterización concluyen que la BHA irradiada a 25 kGy es apropiada para ser utilizada en aplicaciones médicas. | es_PE |
dc.description.abstract | Hydroxyapatite is a material that is used for orthopaedic surgery and traumatology as well as for odontology and maxilo-facial surgery due to its biocompatibility, bioactivity and osteoconduction. To be used in patients, hydroxyapatite must be sterile and thus, previously should undergo an sterilization process. This work aims to characterize a biohydroxyapatite (BHA) sterilized by gamma radiation, treated at doses of 25, 50, 100, 200 y 500 kGy, using gravimetric techniques, FT-IR spectroscopy, X-ray diffraction and fluorescence, scanning electron microscopy as well as organoleptic tests. For product irradiation, dosimetric tests were performed and the sterility of the product was verified through microbiological tests. Results of characterization tests concluded that the BHA irradiated at 25 kGy is appropriate for medical applications. | |
dc.description.sponsorship | Instituto Peruano de Energía Nuclear | |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Lima | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.source | Instituto Peruano de Energía Nuclear | es_PE |
dc.source | Repositorio Institucional del Instituto Peruano de Energía Nuclear | es_PE |
dc.subject | Hidroxiapatita | es_PE |
dc.subject | Radiación gamma | es_PE |
dc.subject | Dosis de radiación | es_PE |
dc.title | Caracterización de una biohidroxiapatita tratada con radiación gamma para aplicaciones biomédicas | es_PE |