Mostrar el registro sencillo del ítem

Caracterización de una biohidroxiapatita tratada con radiación gamma para aplicaciones biomédicas

dc.contributor.authorCastro, Emma
dc.contributor.authorLópez, Alcides
dc.contributor.authorRamos, Bertha
dc.contributor.authorVargas, Johnny
dc.contributor.authorVivanco, Mónica
dc.contributor.authorOlivera, Paula
dc.creatorVivanco, Mónica
dc.creatorOlivera, Paula
dc.creatorLópez, Alcides
dc.creatorVargas, Johnny
dc.creatorCastro, Emma
dc.creatorRamos, Bertha
dc.date.accessioned2014-04-25T17:55:28Z
dc.date.available2014-04-25T17:55:28Z
dc.date.issued2014-01
dc.identifier.citationCastro E, López A, Ramos B, Vargas J, Vivanco M, Olivera P. Caracterización de una biohidroxiapatita tratada con radiación gamma para aplicaciones biomédicas. Informe Científico Tecnológico. 2012; Volumen 12, p. 99-106.es_PE
dc.identifier.issn1684-1662
dc.identifier.urihttps://hdl.handle.net/20.500.13054/137
dc.description.abstractDebido a su excelente biocompatibilidad, bioactividad y osteoconducción, la hidroxiapatita es un material que se utiliza ampliamente en cirugía ortopédica, traumatología, odontología y cirugía maxilo-facial. El presente trabajo tiene como propósito caracterizar una biohidroxiapatita (BHA) esterilizada por radiación gamma y tratada a las dosis de 0, 25, 50, 100, 200 y 500 kGy, utilizando técnicas gravimétricas, espectroscopía FTIR, difracción de rayos X, fluorescencia de rayos X, microscopía electrónica de barrido y pruebas organolépticas. Se realizaron pruebas dosimétricas para la irradiación del producto y la esterilidad de la BHA se comprobó mediante pruebas microbiológicas. Los resultados de las pruebas de caracterización concluyen que la BHA irradiada a 25 kGy es apropiada para ser utilizada en aplicaciones médicas.es_PE
dc.description.abstractHydroxyapatite is a material that is used for orthopaedic surgery and traumatology as well as for odontology and maxilo-facial surgery due to its biocompatibility, bioactivity and osteoconduction. To be used in patients, hydroxyapatite must be sterile and thus, previously should undergo an sterilization process. This work aims to characterize a biohydroxyapatite (BHA) sterilized by gamma radiation, treated at doses of 25, 50, 100, 200 y 500 kGy, using gravimetric techniques, FT-IR spectroscopy, X-ray diffraction and fluorescence, scanning electron microscopy as well as organoleptic tests. For product irradiation, dosimetric tests were performed and the sterility of the product was verified through microbiological tests. Results of characterization tests concluded that the BHA irradiated at 25 kGy is appropriate for medical applications.
dc.description.sponsorshipInstituto Peruano de Energía Nuclear
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherLimaes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectHidroxiapatitaes_PE
dc.subjectRadiación gammaes_PE
dc.subjectDosis de radiaciónes_PE
dc.titleCaracterización de una biohidroxiapatita tratada con radiación gamma para aplicaciones biomédicases_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem