Desarrollo de un software para la calibración de monitores de radiación en un Laboratorio Secundario de Calibraciones Dosimétricas (LSCD)
dc.contributor.author | Rojas, Enrique | |
dc.contributor.author | Benavente, Tony | |
dc.contributor.author | Celedonio, Elder | |
dc.contributor.author | López, Edith | |
dc.creator | López, Edith | |
dc.creator | Benavente, Tony | |
dc.creator | Rojas, Enrique | |
dc.creator | Celedonio, Elder | |
dc.date.accessioned | 2014-04-25T19:05:27Z | |
dc.date.available | 2014-04-25T19:05:27Z | |
dc.date.issued | 2014-01 | |
dc.identifier.citation | Rojas E, Benavente T, Celedonio E, López E. Desarrollo de un software para la calibración de monitores de radiación en un Laboratorio Secundario de Calibraciones Dosimétricas (LSCD). Informe Científico Tecnológico. 2012; Volumen 12, p. 117-119. | es_PE |
dc.identifier.issn | 1684-1662 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13054/140 | |
dc.description.abstract | La calibración dosimétrica de los monitores de radiación, a distintas magnitudes radiológicas, se realiza con el objetivo de obtener medidas exactas, por este motivo el LSCD calcula el factor de calibración dosimétrica y su incertidumbre asociada, para cada rango de uso. El factor de calibración se realiza empleando el método de campos de radiación conocidos y su incertidumbre es calculada siguiendo las recomendaciones de normas ISO. En el LSCD se calcula la incertidumbre expandida (Uc), con un factor de cobertura que brinda un nivel de confianza no menor al 95 %. Para el análisis de los datos durante el proceso de calibración, se ha desarrollado un software utilizando las herramientas de Excel y Visual Basic de Microsoft para que el personal pueda obtener en tiempo real el factor de calibración, incertidumbre asociada, linealidad en la respuesta, etiqueta de calibración y demás datos para la emisión del certificado correspondiente. | es_PE |
dc.description.abstract | The dosimetric calibration of radiation monitors in various radiological quantities are performed in order to obtain accurate measurements, for this reason the SSDL calculated the dosimetric calibration factor and its associated uncertainty for each range of use. The calibration factor is obtained using the method of known radiation fields and the uncertainty is calculated as recommended by the ISO. The SSDL calculates the expanded uncertainty (Uc), with a coverage factor that provides a confidence level not less than 95 %. For the analysis of the data during the calibration process, a software program using MS Excel and Visual Basic tools has been developed in order that the operation personnel in charge of dosimetric calibration could obtain in real time, the calibration factor, the associated uncertainty, linearity in the response, the calibration label and complete data for the issuance of calibration certificate. | |
dc.description.sponsorship | Instituto Peruano de Energía Nuclear | |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Lima | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.source | Instituto Peruano de Energía Nuclear | es_PE |
dc.source | Repositorio Institucional del Instituto Peruano de Energía Nuclear | es_PE |
dc.subject | Programas de ordenadores | es_PE |
dc.subject | Monitores de radiación | es_PE |
dc.subject | Calibración | es_PE |
dc.title | Desarrollo de un software para la calibración de monitores de radiación en un Laboratorio Secundario de Calibraciones Dosimétricas (LSCD) | es_PE |
dc.title.alternative | Development of a software program for the calibration of radiation in Secondary Laboratory for Dosimetric Calibration (SLDC) | es_PE |