Mostrar el registro sencillo del ítem
Sistema de escaneado de alambres de cobre irradiados en el reactor RP-10 usando WSCAN
dc.contributor.author | Arias, Pablo | |
dc.contributor.author | Paez, José | |
dc.contributor.author | Vela, Mariano | |
dc.creator | Vela, Mariano | |
dc.creator | Paez, José | |
dc.creator | Arias, Pablo | |
dc.date.accessioned | 2014-10-23T15:46:37Z | |
dc.date.available | 2014-10-23T15:46:37Z | |
dc.date.issued | 2012 | |
dc.identifier.citation | Pablo Arias, José Paez, Mariano Vela. Sistema de escaneado de alambres de cobre irradiados en el reactor RP-10 usando WSCAN. Informe Científico Tecnológico. Volumen 11 (2011) p. 57-61. | es_PE |
dc.identifier.issn | 1684-1662 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13054/237 | |
dc.description.abstract | Presentamos el diseño de un sistema para el escaneado de alambres de cobre irradiados en el núcleo del reactor RP-10, mediante una cadena de instrumentación nuclear se mide la tasa de irradiación en varios puntos del alambre, permitiendo obtener el perfil de dicho parámetro. El sistema es controlado por un programa elaborado en LabVIEW que permite establecer las condiciones de escaneo, almacenar las mediciones de tasas de irradiación en cada punto del alambre así como graficar el perfil medido. Este sistema permite la interacción con alambres de cobre de alta tasa de irradiación al minimizar el tiempo de exposición del investigador, muy buena precisión a mediciones igualmente espaciadas con un error menor a 0.01 mm y el almacenamiento de los datos para posterior análisis. | es_PE |
dc.description.abstract | We introduce the design of a system for scanning copper wires irradiated in the RP-10 reactor, which allows to measure the rate of radiation at several points of the wire, through a suitable nuclear instrumentation chain, allowing to obtain the profile of the mentioned parameter. The system is controlled by a program developed in LabView that allows the setting of scanning conditions, store irradiation rate measurements at each point of the wire and plots the measured profile. This system is able to work with copper wires of high irradiation rate minimizing the exposure time of the investigator, with very good accuracy at equally spaced measurements, with an error less than 0.01 mm and storing data for later analysis. | |
dc.description.sponsorship | Instituto Peruano de Energía Nuclear | |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Lima | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.source | Instituto Peruano de Energía Nuclear | es_PE |
dc.source | Repositorio Institucional del Instituto Peruano de Energía Nuclear | es_PE |
dc.subject | Reactor RP-10 | es_PE |
dc.subject | Alambres | es_PE |
dc.subject | Dispositivos de irradiación | es_PE |
dc.subject | Cálculos por ordenadores | es_PE |
dc.subject | Cobre | es_PE |
dc.subject | Dosis de radiación | es_PE |
dc.title | Sistema de escaneado de alambres de cobre irradiados en el reactor RP-10 usando WSCAN | es_PE |
dc.title.alternative | Scanning system copper wire irradiated in RP-10 reactor using WSCAN | es_PE |
dc.type | info:eu-repo/semantics/article | es_PE |
dc.publisher.country | PE | es_PE |