Buscar
Mostrando ítems 1-10 de 20
Evaluación ambiental de ecosistemas altamente sensibles: Uso de líquenes como biomonitores
(Lima, 2002-06)
Se presentan los resultados preliminares de los estudios poblacionales de líquenes de tres ecosistemas diferentes; así como, los contenidos de elementos trazas ensayadas por activación neutrónica en las muestras de líquenes ...
The set Au - Zr - Mo - Cr - Lu as multiple reactor flux monitor: The performance of Zr-96 and the analysis of inconsistencies
(Lima (Perú), 2008-11)
The simultaneous use of Au, Zr, Mo, Cr and Lu, for the characterization of irradiation facilities with the purpose of parametric neutron activation analysis, reveals some systematic inconsistencies in the determination of ...
Study of the production and distribution of middle horizon pottery of Cuzco, Perú by k_0-based instrumental neutron activation analysis
(Lima, 2002-06)
The objective of the present research was to establish, in general terms, the provenience of certain pottery styles dating to the Middle Horizon which are known to the Southern Highlands, Cuzco region. The specific goal ...
Pruebas preliminares de preconcentración y eliminación de matriz en muestras de agua de mar para su análisis por fluorescencia de rayos-x en reflexión total.
(Lima, 2002-06)
Se ha comprobado experimentalmente, luego de varias pruebas preliminares, que la técnica más adecuada de separación, preconcentra-ción y recuperación de Co, Ni, Cu, Zn y Pb en muestras de agua de mar, para su deter-minación ...
Avances en la construcción del sistema neumático de transporte de muestras para el reactor RP-10
(Lima (perú), 2008-11)
En el presente trabajo se describe el diseño y construcción de un sistema neumático de transferencia de muestras para su irradiación, en una posición de la grilla del núcleo del reactor, y la aplicación de la técnica de ...
Importancia de la técnica de activación neutrónica para el análisis de elementos traza en materiales biológicos
(Lima (Perú), 2008-11)
El estudio de materiales biológicos actualmente tiene un interés creciente, por la importancia que tiene el conocimiento de la concentración de los elementos traza esenciales y tóxicos, para determinar los efectos que ...
Determination of trace elements in water samples by k0 based instrumental neutron activation analysis using sodium as comparator
(Lima, 2003-07)
Neutron Activation Analysis in liquid samples has been a challenge for our laboratory due to the following difficulties: i) to irradiate samples in the polyethylene vials avoiding pressure build up ii) to get an appropriate ...
Determination of trace elements and heavy metals in agricultural products cultivated at the Rimac river valley in Lima city using nuclear and related analytical techniques
(Lima (Perú), 2004-08)
There are strong indications that the Rimac river valley is being contaminated with heavy metals and an excess of trace elements that come from some industrial and mining activities developed along the Rimac river valley. ...
Evaluación de las interferencias umbrales en la determinación de Mg y Cr por análisis por activación neutrónica
(Lima, 2002-06)
La determinación del Mg y Cr mediante el análisis por activación neutrónica implica la evaluación de las interferencias umbrales como probables fuentes de variación sistemática la cual se efectúa mediante el empleo ...
Aplicación de la técnica analítica de activación neutrónica en el análisis multielemental de la hoja de coca
(Lima (Perú), 2007-08)
El análisis por activación neutrónica basado en el método k sub-cero (k0 - NAA) ha sido utilizado para cuantificar veintiséis elementos mayores, menores y traza en muestras de hojas de coca en polvo procedentes de diferentes ...