Mostrar el registro sencillo del ítem
Conmutación automática de emergencia del sistema de ventilación del reactor nuclear RP-10
dc.contributor.author | Castillo, Walter | |
dc.contributor.author | Corimanya, Marco | |
dc.contributor.author | Ovalle, Edgar | |
dc.contributor.author | Anaya, Olgger | |
dc.contributor.author | Veramendi, Emilio | |
dc.creator | Anaya, Olgger | |
dc.creator | Veramendi, Emilio | |
dc.creator | Corimanya, Marco | |
dc.creator | Castillo, Walter | |
dc.creator | Ovalle, Edgar | |
dc.date.accessioned | 2015-05-22T20:38:16Z | |
dc.date.available | 2015-05-22T20:38:16Z | |
dc.date.issued | 2014-11 | |
dc.identifier.citation | Castillo Walter, et al. Conmutación automática de emergencia del sistema de ventilación del reactor nuclear RP-10. Informe Científico Tecnológico. Volumen 13 (2013) p. 147-150. | es_PE |
dc.identifier.issn | 1684-1662 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13054/318 | |
dc.description.abstract | En el presente trabajo se resume los logros alcanzados en el diseño e implementación de un sistema de supervisión y control automático de los efluentes radiactivos que salen por la chimenea del reactor RP-10, utilizando como hardware una plataforma Arduino Uno, que contiene un micro controlador programable ATMEGA 328, al que se ha adicionado una pantalla LCD para visualizar los valores, un teclado y una memoria de datos EEPROM donde se fija el valor límite del nivel de radiación. El nivel de radiación del aire del hall del reactor, al pasar por la chimenea, es censado por un monitor de radiación denominado MAB1000 y los datos son suministrados al nuevo sistema. Cuando el nivel de radiación está por encima de las normas nacionales e internacionales, el nuevo diseño hace actuar un relé para que el sistema de ventilación sea conmutado automáticamente para funcionar en la condición de emergencia, evitando la liberación de contaminantes radiactivos al medioambiente. Una vez instalado el nuevo diseño, se ha verificado que el valor cesado por el monitor de radiación MAB1000 es idéntico al mostrado en el nuevo sistema. Adicionalmente, se ha probado con fuentes radiactivas la actuación del relé para conmutar el sistema de ventilación a la condición de emergencia en forma exitosa. | es_PE |
dc.description.abstract | The present paper summarizes the achievements in the design and implementation of a system for monitoring and automatic control of radioactive effluents from the chimney of the reactor RP-10, using as hardware an Arduino platform UNO containing a ATMEGA 328 programmable micro controller to which has been added an LCD screen to display the values, a keyboard and a memory data EEPROM, where the limit of the level of radiation is fixed. The radiation level in the air of the reactor hall, going up the chimney is counted by a radiation monitor called MAB1000, and data are supplied to the new system. When the radiation level is above the national and international standards, the new design makes it act a relay, so that the ventilation system is automatically switched to operate in emergency condition, preventing the release of radioactive contaminants into the environment. After installing the new design, it was verified that removed by the radiation monitor MAB1000, value is identical to that shown in the new system. Additionally, it was tested with radioactive sources acting relay to switch the ventilation system to the emergency condition successfully. | |
dc.description.sponsorship | Instituto Peruano de Energía Nuclear | |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Lima | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.source | Instituto Peruano de Energía Nuclear | es_PE |
dc.source | Repositorio Institucional del Instituto Peruano de Energía Nuclear | es_PE |
dc.subject | Reactor RP-10 | es_PE |
dc.subject | Sistemas de ventilación | es_PE |
dc.subject | Efluentes radiactivos | es_PE |
dc.subject | Efluentes gaseosos | es_PE |
dc.subject | Vigilancia de la radiactividad | es_PE |
dc.subject | Protección contra las radiaciones | es_PE |
dc.subject | Diseños | es_PE |
dc.title | Conmutación automática de emergencia del sistema de ventilación del reactor nuclear RP-10 | es_PE |
dc.type | info:eu-repo/semantics/article | es_PE |
dc.publisher.country | PE | es_PE |