Mostrar el registro sencillo del ítem
Caracterización y puesta a punto de la facilidad de neutrografía del Reactor Nuclear RP-10
dc.contributor.author | Ravello Ratzenberg, Yuri Roger | |
dc.creator | Ravello Ratzenberg, Yuri Roger | |
dc.date.accessioned | 2015-05-25T17:05:57Z | |
dc.date.available | 2015-05-25T17:05:57Z | |
dc.date.issued | 2001 | |
dc.identifier.citation | Ravello Ratzenberg Yuri Roger. Caracterización y puesta a punto de la facilidad de neutrografía del Reactor Nuclear RP-10. [Tesis para optar el Título del Licenciado en Ciencias. Mención: Física]. Lima, Perú: Universidad Nacional de Ingeniería, Facultad de Ciencias. Escuela Profesional de Física; 2001. | es_PE |
dc.identifier.uri | https://hdl.handle.net/20.500.13054/319 | |
dc.description.abstract | El presente trabajo de investigación tuvo el objetivo de caracterizar y poner a punto la facilidad de neutrografía del reactor nuclear RP-10, y así con ésta técnica de inspección poder brindar servicios a la industria y centros de investigación en general. Esta técnica se complementará con las técnicas existentes en el mercado nacional como la radiografía X y la gammagrafía. Para ello se determinó en primer lugar la capacidad del blindaje de la facilidad, dando como resultado que éste satisface los requerimientos de protección radiológica establecidos en el Reglamento de Seguridad Radiológica. Luego, se realizaron ensayos de filtrado gamma con el fin de implementar el método directo de formación de imagen, se construyeron las curvas de densidad óptica en función del espesor del filtro gamma, del tipo de película y del tiempo de irradiación. Asimismo, se implementó el método indirecto de formación de imagen para dos tipos de convertidores: indio y disprosio. Se construyeron también curvas de crecimiento de densidad óptica en función del tiempo de contacto convertidor-película, para diferentes tipos de películas. Además, se determinó la resolución de la facilidad, para lo cual se emplearon dos métodos: Klasens (1946) y Harms (1986). Se obtuvo como resultado que el método de Harms se aproximó más a la capacidad de resolución del ojo humano que el método de Klasens. Finalmente, se presentan los campos de aplicaciones de la neutrografía, incluyendo algunas que se realizaron con la facilidad de neutrografía del reactor nuclear RP-10. Con todo lo realizado, la facilidad de neutrografía del RP-10 ha quedado expedita para la prestación de servicios de inspección e investigación. | es_PE |
dc.description.abstract | The main aim of this work was to characterize and adjust the neutron radiography facility of the RP-10 nuclear reactor, and therefore be able to offer with this technique services to the industry and research centers in general. This technique will be complemented with others such as X-Rays and gamma radiography. First, the shielding capacity of the facility was analyzed, proving that it complies with the radiological safety requirements established by the Radiological Safety Code. Then, gamma filtration tests were conducted in order to implement the direct method for image formation, optical density curves were built according to the thickness of the gamma filter, the type of film and the type of irradiation. Also, the indirect method for image formation was implemented for two types of converters: indium and dysprosium. Growth curves for optical density were also made according to contact time between converter-film, for different types of films. The resolution of the facility was also analyzed using two methods: Klasens (1946) and Harms (1986). Harms method came closer to the resolution of the human eye when compared to the Klasens method. Finally, the application fields of neutron radiography are presented, including those conducted at the neutron radiography facility of the RP-10 nuclear reactor. With this work, the RP-10 neutron radiography facility is ready to offer inspection and research services. | |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Lima (Perú) | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.source | Instituto Peruano de Energía Nuclear | es_PE |
dc.source | Repositorio Institucional del Instituto Peruano de Energía Nuclear | es_PE |
dc.subject | Neutrografía | es_PE |
dc.subject | Reactor RP-10 | es_PE |
dc.subject | Ensayo no destructivo | es_PE |
dc.subject | Colimadores | es_PE |
dc.subject | Tratamiento de imágenes | es_PE |
dc.subject | Haces de neutrones | es_PE |
dc.subject | Flujo de neutrones | es_PE |
dc.subject | Instalaciones fuentes de neutrones | es_PE |
dc.title | Caracterización y puesta a punto de la facilidad de neutrografía del Reactor Nuclear RP-10 | es_PE |
dc.title.alternative | Characterization and adjustment of the neutron radiography facility of the RP-10 Nuclear Reactor | es_PE |
dc.type | info:eu-repo/semantics/bacherlorThesis | es_PE |
dc.publisher.country | PE | es_PE |
thesis.degree.discipline | Física | es_PE |
thesis.degree.grantor | Universidad Nacional de Ingeniería. Facultad de Ciencias | es_PE |
thesis.degree.name | Licenciado en Ciencias mención en Física | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Tesis de Grado [17]