Efecto de la radiación en el envejecimiento de los materiales de cables coaxiales utilizados en el sistema de instrumentación neutrónica del reactor RP-10

dc.contributor.authorArrieta, Rolando
dc.contributor.authorLópez, Alcides
dc.contributor.authorUrcia, Agustín
dc.creatorUrcia, Agustín
dc.creatorArrieta, Rolando
dc.creatorLópez, Alcides
dc.date.accessioned2015-05-28T16:59:05Z
dc.date.available2015-05-28T16:59:05Z
dc.date.issued2013-01
dc.identifier.citationLópez A, et al. Efecto de la radiación en el envejecimiento de los materiales de cables coaxiales utilizados en el sistema de instrumentación neutrónica del reactor RP-10. Informe Científico Tecnológico. Volumen 11 (2011) p. 39-43.es_PE
dc.identifier.issn1684-1662
dc.identifier.urihttps://hdl.handle.net/20.500.13054/330
dc.description.abstractSe presenta el estudio del envejecimiento de los materiales del sistema de instrumentación neutrónica en el reactor RP-10 mediante análisis morfológico comparativo de los plásticos empleados como aislantes de un cable coaxial nuevo e irradiado en su posición de trabajo próximo al núcleo del reactor nuclear por un tiempo aproximado de un año. A través de un análisis fractográfico por microscopía electrónica de barrido y por microscopía electrónica de transmisión se comparó a nivel macroscópico las superficies exteriores, las secciones transversales microscópicas, observándose que a mayor dosis de radiación los plásticos se vitrifican y forman burbujas internas que crecen, produciéndose tensiones internas que fracturan la matriz y disminuyen sus propiedades aislantes, resultados importantes que servirán para la toma de decisiones de reparación o sustitución de los componentes afectados por el envejecimiento debido al cambio de propiedades inducidos por radiación de neutrones.es_PE
dc.description.abstractIn this work we show the study of aging of the materials applied on neutron instrumentation system, by performing comparative morphological analysis of the plastics used as insulation, in a new and irradiated coaxial cable in its working position, close to the core of the Nuclear Reactor RP-10, for a time approximately of one year. Macroscopic analysis of the exterior surfaces fractography was performed by scanning and transmission electron microscopy, also microscopic cross sections were analyzed, showing that higher doses of radiation induce vitrification of the plastics, with internal bubbles that grow, producing internal stress, fracture and reducing their insulator properties of the matrix, these important results serve to decision making, about repair or replacement of the components affected by ageing caused by the neutron induced radiation.
dc.description.sponsorshipInstituto Peruano de Energía Nuclear
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherLimaes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectEndurecimiento por envejecimientoes_PE
dc.subjectEnvejecimientoes_PE
dc.subjectReactor RP-10es_PE
dc.subjectComponentes del reactores_PE
dc.subjectCambios morfológicoses_PE
dc.subjectDosis de radiaciónes_PE
dc.subjectReactores de investigación y ensayoes_PE
dc.titleEfecto de la radiación en el envejecimiento de los materiales de cables coaxiales utilizados en el sistema de instrumentación neutrónica del reactor RP-10es_PE