Monitoreo de potencia del reactor RP-10 mediante la medición de la actividad del 16-N: Avances de proyecto

dc.contributor.authorFélix, José
dc.contributor.authorVela, Mariano
dc.contributor.authorArrieta, Rolando
dc.creatorArrieta, Rolando
dc.creatorVela, Mariano
dc.creatorFélix, José
dc.date.accessioned2015-05-28T19:18:37Z
dc.date.available2015-05-28T19:18:37Z
dc.date.issued2013-01
dc.identifier.citationFélix J, et al. Monitoreo de potencia del reactor RP-10 mediante la medición de la actividad del 16-N: Avances de proyecto. Informe Científico Tecnológico. Volumen 11 (2011) p. 62-66.es_PE
dc.identifier.issn1684-1662
dc.identifier.urihttps://hdl.handle.net/20.500.13054/333
dc.description.abstractEn una instalación nuclear es necesario tener sistemas redundantes y diversos de medición, presentamos un sistema adicional para monitorear la potencia del reactor nuclear RP-10, mediante la medición de la actividad radiactiva gamma del 16N contenido en el refrigerante. Se describe la instalación de un prototipo, después de elegir y optimizar la ubicación de un detector de radiación (cámara de ionización) que fue sometido a diversas pruebas a fin de recolectar, acondicionar y trasmitir una corriente proporcional a la potencia hasta el punto de medición; luego, los valores leídos fueron contrastados con los reportados por el sistema que mide la potencia térmica teniendo como referencia las corrientes que nos proporciona las cadenas de marcha. Finalmente se instaló en la consola de comando de sala de control a la espera de su instalación definitiva con equipos adquiridos para este propósito. Se ha logrado la operatividad del RP-10 con un sistema adicional usando distinto principio físico que la hace más confiable.es_PE
dc.description.abstractIn a nuclear plant must have redundant and diverse systems of measurement, we introduce an additional one, for monitoring the power of the RP-10 nuclear reactor, by measuring the gamma radiation activity of 16N content in the coolant. We describe an installation of a prototype after choosing and optimizing the location of a radiation detector (ionization chamber) that was subjected to various tests to collect, adjust and pass a current proportional to the power to the measurement point, then the read values were compared with those reported by the system that measures the thermal power, using as a reference the currents provided by the working instrumentation chains. Finally, the proposed system was installed into the command console control room, waiting for final installation with equipment purchased for this purpose. It has managed the operation of the RP-10 reactor with an additional system using different physical principle that makes more reliable.
dc.description.sponsorshipInstituto Peruano de Energía Nuclear
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherLimaes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectReactor RP-10es_PE
dc.subjectNitrógeno 16es_PE
dc.subjectRadiación térmicaes_PE
dc.subjectReactores de investigación y ensayoes_PE
dc.titleMonitoreo de potencia del reactor RP-10 mediante la medición de la actividad del 16-N: Avances de proyectoes_PE