Mostrar el registro sencillo del ítem

Estudio de la interconexión de filtraciones y surgencias de bocaminas aguas abajo de una mina en Huancavelica

dc.contributor.authorValencia, Jacinto
dc.contributor.authorMamani, Enoc
dc.contributor.authorMaguiña, José
dc.contributor.authorCondori, Jorge
dc.creatorMamani, Enoc
dc.creatorCondori, Jorge
dc.creatorValencia, Jacinto
dc.creatorMaguiña, José
dc.date.accessioned2015-06-03T16:17:16Z
dc.date.available2015-06-03T16:17:16Z
dc.date.issued2013-01
dc.identifier.citationValencia J, et al. Estudio de la interconexión de filtraciones y surgencias de bocaminas aguas abajo de una mina en Huancavelica. Informe Científico Tecnológico. Volumen 11 (2011) p. 69-71.es_PE
dc.identifier.issn1684-1662
dc.identifier.urihttps://hdl.handle.net/20.500.13054/334
dc.description.abstractEn el presente trabajo se muestran los resultados del análisis isotópicos de O-18 y H-2 en muestras de agua de probable interconexión de filtraciones y surgencias de bocaminas aguas abajo de una mina en Huancavelica. Los resultados hallados nos indica que las aguas de las filtraciones están mezcladas con aguas termales de origen profundo que incrementan los valores isotópicos y adoptan en el diagrama O-18/H-2, la tendencia hacia el campo de las aguas magmáticas, propias de los sistemas geotérmicos; a diferencia de las aguas de surgencias de bocaminas que muestran empobrecimiento isotópico de O-18 y H-2. En el contexto general del área bajo estudio de la mina tiene en consideración los resultados de los análisis isotópicos se concluye que las aguas de filtraciones de mina no tienen relación con las surgencias de las bocaminas, distantes a 8 km aguas abajo.es_PE
dc.description.abstractThe present work shows the results of isotopic analysis of O-18 and H-2 of water samples with probable interconnection of pithead of leaks and seeps downstream from a mine in Huancavelica. The results found indicates us, that the waters of the leaks are mixed with thermal water of deep origin which increase the isotopic values and adopted in the diagram O-18/H-2, the tendency towards the field of magmatic waters, typical of geothermal systems, unlike upwelling waters pithead showing impoverishment in isotopic O-18 and H-2. In the general context of the study area of the mine relate to expenses incurred in consideration the results of isotopic analyzes concluded that the mine water leaks are unrelated to upwelling of pitheads, distant 8 km downstream.
dc.description.sponsorshipInstituto Peruano de Energía Nuclear
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherLimaes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectAnálisis isotópicoes_PE
dc.subjectHidrología isotópicaes_PE
dc.subjectOxígeno 18es_PE
dc.subjectHidrógeno 2es_PE
dc.subjectAguas subterráneases_PE
dc.subjectMinases_PE
dc.subjectAguas termaleses_PE
dc.subjectEspectrometríaes_PE
dc.titleEstudio de la interconexión de filtraciones y surgencias de bocaminas aguas abajo de una mina en Huancavelicaes_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem