Mostrar el registro sencillo del ítem

Desarrollo y aplicación de la metodología fish en el estudio de los efectos de las radiaciones ionizantes

dc.contributor.authorEspinoza, Marco
dc.contributor.authorOliveros, N.
dc.contributor.authorQuintana, M.
dc.contributor.authorMontez, R.
dc.creatorOliveros, N.
dc.creatorMontez, R.
dc.creatorEspinoza, Marco
dc.creatorQuintana, M.
dc.date.accessioned2015-06-24T16:05:49Z
dc.date.available2015-06-24T16:05:49Z
dc.date.issued2003-07
dc.identifier.citationEspinoza M, et al. Desarrollo y aplicación de la metodología fish en el estudio de los efectos de las radiaciones ionizantes. Informe Científico Tecnológico. Volumen 2 (2002) p. 136-141.es_PE
dc.identifier.issn1684-1662
dc.identifier.urihttps://hdl.handle.net/20.500.13054/361
dc.description.abstractSe muestran los resultados de la estandarización y uso de una técnica para hacer la hibridización in situ con fluorescencia (FISH) en el Laboratorio de Citogenética y Radiobiología del Instituto Peruano de Energía Nuclear (IPEN). Tras una búsqueda de información bibliográfica se decidió trabajar con el método que emplea sondas para cromosoma total marcadas con un fluorocromo de emisión verde (WCP). Se hizo el estudio con dos muestras de sangre irradiadas y una muestra control. Las dosis suministradas a dos de las muestras fueron 0.75 y 1.8 Gy de rayos gamma del Co-60. Por razones de tipo económico se tuvo que trabajar tan solo con las sondas para los cromosomas 1 y 2. Eso ha causado que nuestra eficiencia para detectar translocaciones por FISH haya sido baja (25%) siendo usual en otros laboratorios trabajar con eficiencias de alrededor del 33% para lo cual debemos incluir al menos tres pares de cromosomas. Como consecuencia de lo anterior la proporción de dicéntricos y translocaciones en la muestra de células estudiadas no concuerda con lo esperado: 1 dicéntrico por cada translocación.es_PE
dc.description.abstractResults of standardization work and use of a methodology for fluorescence in situ hibridization (FISH) under development in the Cytogenetics and Radiobiology Laboratory of Peruvian Nuclear Energy Institute (IPEN), are shown. After searching for scientific literature, it was decided to work with a method that employs whole chromosome probes (WCP) labeled with a spectrum green fluorochrome. The study was perform using two irradiated blood samples and a control one. Doses delivered were 0.75 and 1.8 Gy of gamma rays from Co-60. For economical reasons, it was necessary to buy only WCP FISH probes for chromosomes 1 and 2. This situation has occasioned that the efficiency to detect FISH translocations is poor (about 25%) and in the meanwhile, other laboratories around the world are getting near 33% of efficiency working with three pairs of chromosomes in order to reach 33% of efficiency. As a consequence of this, the proportion of dicentrics and translocations found in our samples does not agree with expected values: 1 dicentric for each translocation.
dc.description.sponsorshipInstituto Peruano de Energía Nuclear
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherLima (Perú)es_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectEfectos biológicos de las radiacioneses_PE
dc.subjectRadiaciones ionizanteses_PE
dc.subjectHibridizaciónes_PE
dc.subjectDosis de radiaciónes_PE
dc.subjectDosimetría biológicaes_PE
dc.subjectExposición a la radiaciónes_PE
dc.titleDesarrollo y aplicación de la metodología fish en el estudio de los efectos de las radiaciones ionizanteses_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem