Marcación del anticuerpo monoclonal IOR-CEA1 con I-131 por el método de la cloramina T, para el diagnóstico precoz de enfermedades neoplásicas relacionadas con el adenocarcinoma embrionario: Reporte Preliminar

dc.contributor.authorKoga, Roberto
dc.contributor.authorVásquez, Silvia
dc.contributor.authorOtero, Manuel
dc.contributor.authorCaballero, José
dc.contributor.authorHerrera, Jorge
dc.creatorCaballero, José
dc.creatorHerrera, Jorge
dc.creatorVásquez, Silvia
dc.creatorKoga, Roberto
dc.creatorOtero, Manuel
dc.date.accessioned2015-07-08T14:45:32Z
dc.date.available2015-07-08T14:45:32Z
dc.date.issued2004-08
dc.identifier.citationKoga R, et al. Marcación del anticuerpo monoclonal IOR-CEA1 con I-131 por el método de la cloramina T, para el diagnóstico precoz de enfermedades neoplásicas relacionadas con el adenocarcinoma embrionario: Reporte Preliminar. Informe Científico Tecnológico. Volumen 3 (2003) p. 65-67.es_PE
dc.identifier.issn1684-1662
dc.identifier.urihttps://hdl.handle.net/20.500.13054/390
dc.description.abstractEl Anticuerpo Monoclonal (AcMo) IOR-CEA1 es considerado como un marcador tumoral para cáncer al colón y recto principalmente. Con ayuda de las técnicas nucleares se ha logrado marcar el radioisótopo I-131, que se produce en la Planta de Producción de Radioisótopos del IPEN. El AcMo IOR-CEA1 con el I-131, fue marcado inicialmente según la técnica de la Cloramina T, descrita en la “Guía de radioiodonización de Amersham Life Science”, donde no se obtuvieron resultados favorables y por esa razón se realizaron variantes, debido a que no se ligaba el anticuerpo con el I-131, por lo que se modificó esta técnica aumentando el tiempo de incubación y concentración del agente oxidante (Cloramina T), lo que dio como resultado porcentaje promedio de pureza en radioquímica un porcentaje promedio (PQR) del 97,57% ± 1,53, además se evaluó la estabilidad de la molécula teniendo como resultado que hasta el sexto día de la post-marcación presenta una PRQ >90%.es_PE
dc.description.abstractThe Monoclonal antibody (AcMo) IOR-CEA1 is considered a tumor marker for colon and rectal cancer. With the aid of nuclear techniques it was to label with the radioisotope I-131 that is produced in the Plant of Production of Radioisotopes in IPEN. The monoclonal antibody according to the techniques of the Chloramine T, described in the 'Guide of radioidonation of Amersham life'. We did not obtained a good result and for this reason we made modifications due to that the antibody with the I-131 was tied, in this technique of the oxidant agent (Chloramine T), was incubated for more time and the concentration was increased too. Having as a result in the radiochemical purity (PQR) a percentage average of the 97,57%±1,53; also the stability of the labelled molecule was evaluated having as a result that until the sixth day of the post-labelled we had a molecule with a PQR > 90%.
dc.description.sponsorshipInstituto Peruano de Energía Nuclear
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherLima (Perú)es_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectAnticuerpos monoclonaleses_PE
dc.subjectYodo 131es_PE
dc.subjectCloraminases_PE
dc.subjectCánceres_PE
dc.subjectAdenocarcinomases_PE
dc.titleMarcación del anticuerpo monoclonal IOR-CEA1 con I-131 por el método de la cloramina T, para el diagnóstico precoz de enfermedades neoplásicas relacionadas con el adenocarcinoma embrionario: Reporte Preliminares_PE
dc.title.alternativeLabelling of monoclonal antibody IOR-CEA1, with I-131 for the method of chloramine T, for the early diagnosis of carcinoembryonic antigen: Preliminary reportes_PE