Evaluación de la incertidumbre en el valor de la reactividad del núcleo 25 del reactor RP-10 mediante el modelo cinético puntual y espacial
dc.contributor.author | Zapata, Magaly | |
dc.contributor.author | Zúñiga, Agustín | |
dc.contributor.author | Bruna, Rubén | |
dc.creator | Bruna, Rubén | |
dc.creator | Zúñiga, Agustín | |
dc.creator | Zapata, Magaly | |
dc.date.accessioned | 2015-07-15T20:09:45Z | |
dc.date.available | 2015-07-15T20:09:45Z | |
dc.date.issued | 2005-08 | |
dc.identifier.citation | Zapata M, Zúñiga A, Bruna R. Evaluación de la incertidumbre en el valor de la reactividad del núcleo 25 del reactor RP-10 mediante el modelo cinético puntual y espacial. Informe Científico Tecnológico. Volumen 4 (2004) p. 74-77. | es_PE |
dc.identifier.issn | 1684-1662 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13054/420 | |
dc.description.abstract | Uno de parámetros requeridos para la licencia de operación del reactor, es el valor del Exceso de Reactividad del núcleo; siendo para ello necesario conocer los valores del peso de las barras de control. En el RP-10 se han utilizado los modelos cinéticos puntual y espacial para la calibración y el Rod-Drop de las barras, habiéndose encontrado discrepancias en la reproducibilidad de los resultados cuando se modifica la secuencia de las mismas. El presente trabajo establece dos hipótesis como causas principales de estas discrepancias; primero, el efecto de la ubicación de los detectores (dos cámaras de ionización compensada) en el núcleo; segundo, el efecto de apantallamiento entre dos barras de control. Los resultados mostraron que las discrepancias podían ser explicadas por las hipótesis planteadas y en consecuencia se pudo determinar las incertezas y el exceso de reactividad del núcleo. | es_PE |
dc.description.abstract | One of the parameters required in the operation license of a particular core configuration in a nuclear reactor is the reactivity excess, value that we need to determine the control rod worth. The usual methodology is based on Point Kinetics and Spatial Kinetics Models. In RP-10, we use these models by the rod drop method and discrepancies have been observed in the reproducibility of the results when we modify the sequences of the control rods used in the measurements. This paper is a study of the situation where we have established two hypothesis as main causes. First, the effect of the detector locations (two compensated ionization chambers); and second, the control rods interference which would be produced by the neutron flux redistribution. In the experiment, we have used two detectors and the inverse kinetics as a method. The results have confirmed that these discrepancies can be explained by the two causes mentioned above; then we could determine the uncertainty in the control rod worth besides the reactivity excess of the core configuration. | |
dc.description.sponsorship | Instituto Peruano de Energía Nuclear | |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Lima (Perú) | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.source | Instituto Peruano de Energía Nuclear | es_PE |
dc.source | Repositorio Institucional del Instituto Peruano de Energía Nuclear | es_PE |
dc.subject | Método de caída de barra | es_PE |
dc.subject | Reactor RP-10 | es_PE |
dc.subject | Cinética de los reactores | es_PE |
dc.subject | Eficacia de las barras de control | es_PE |
dc.title | Evaluación de la incertidumbre en el valor de la reactividad del núcleo 25 del reactor RP-10 mediante el modelo cinético puntual y espacial | es_PE |