Mostrar el registro sencillo del ítem

Evaluación de la incertidumbre en el valor de la reactividad del núcleo 25 del reactor RP-10 mediante el modelo cinético puntual y espacial

dc.contributor.authorZapata, Magaly
dc.contributor.authorZúñiga, Agustín
dc.contributor.authorBruna, Rubén
dc.creatorBruna, Rubén
dc.creatorZúñiga, Agustín
dc.creatorZapata, Magaly
dc.date.accessioned2015-07-15T20:09:45Z
dc.date.available2015-07-15T20:09:45Z
dc.date.issued2005-08
dc.identifier.citationZapata M, Zúñiga A, Bruna R. Evaluación de la incertidumbre en el valor de la reactividad del núcleo 25 del reactor RP-10 mediante el modelo cinético puntual y espacial. Informe Científico Tecnológico. Volumen 4 (2004) p. 74-77.es_PE
dc.identifier.issn1684-1662
dc.identifier.urihttps://hdl.handle.net/20.500.13054/420
dc.description.abstractUno de parámetros requeridos para la licencia de operación del reactor, es el valor del Exceso de Reactividad del núcleo; siendo para ello necesario conocer los valores del peso de las barras de control. En el RP-10 se han utilizado los modelos cinéticos puntual y espacial para la calibración y el Rod-Drop de las barras, habiéndose encontrado discrepancias en la reproducibilidad de los resultados cuando se modifica la secuencia de las mismas. El presente trabajo establece dos hipótesis como causas principales de estas discrepancias; primero, el efecto de la ubicación de los detectores (dos cámaras de ionización compensada) en el núcleo; segundo, el efecto de apantallamiento entre dos barras de control. Los resultados mostraron que las discrepancias podían ser explicadas por las hipótesis planteadas y en consecuencia se pudo determinar las incertezas y el exceso de reactividad del núcleo.es_PE
dc.description.abstractOne of the parameters required in the operation license of a particular core configuration in a nuclear reactor is the reactivity excess, value that we need to determine the control rod worth. The usual methodology is based on Point Kinetics and Spatial Kinetics Models. In RP-10, we use these models by the rod drop method and discrepancies have been observed in the reproducibility of the results when we modify the sequences of the control rods used in the measurements. This paper is a study of the situation where we have established two hypothesis as main causes. First, the effect of the detector locations (two compensated ionization chambers); and second, the control rods interference which would be produced by the neutron flux redistribution. In the experiment, we have used two detectors and the inverse kinetics as a method. The results have confirmed that these discrepancies can be explained by the two causes mentioned above; then we could determine the uncertainty in the control rod worth besides the reactivity excess of the core configuration.
dc.description.sponsorshipInstituto Peruano de Energía Nuclear
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherLima (Perú)es_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectMétodo de caída de barraes_PE
dc.subjectReactor RP-10es_PE
dc.subjectCinética de los reactoreses_PE
dc.subjectEficacia de las barras de controles_PE
dc.titleEvaluación de la incertidumbre en el valor de la reactividad del núcleo 25 del reactor RP-10 mediante el modelo cinético puntual y espaciales_PE
dc.title.alternativeUncertainty evaluation to determine the reactivity excess of a 25 nuclear core configuration in the RP-10 reactor using point kinetic and spatial modelses_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.publisher.countryPEes_PE