Mostrar el registro sencillo del ítem

Aplicación de la técnica analítica de activación neutrónica en el análisis multielemental de la hoja de coca

dc.contributor.authorTorres, Blanca
dc.contributor.authorBedregal, Patricia
dc.contributor.authorMendoza, Pablo
dc.contributor.authorUbillús, Marco
dc.creatorUbillús, Marco
dc.creatorBedregal, Patricia
dc.creatorTorres, Blanca
dc.creatorMendoza, Pablo
dc.date.accessioned2015-09-09T17:19:51Z
dc.date.available2015-09-09T17:19:51Z
dc.date.issued2007-08
dc.identifier.citationTorres B, Bedregal P, et al. Aplicación de la técnica analítica de activación neutrónica en el análisis multielemental de la hoja de coca. Informe Científico Tecnológico. Volumen 6 (2006) p. 50-53.es_PE
dc.identifier.issn1684-1662
dc.identifier.urihttps://hdl.handle.net/20.500.13054/488
dc.description.abstractEl análisis por activación neutrónica basado en el método k sub-cero (k0 - NAA) ha sido utilizado para cuantificar veintiséis elementos mayores, menores y traza en muestras de hojas de coca en polvo procedentes de diferentes regiones del Perú. Las muestras fueron irradiadas en el reactor RP-10 del Centro Nuclear RACSO, utilizando el sistema neumático de transferencia de muestras, para cuantificar elementos de período de semidesintegración corto y la posición A-9 de la grilla del núcleo del reactor, para la determinación de elementos de período de semidesintegración intermedio y largo. Con la finalidad de asegurar la calidad de los resultados obtenidos, se analizaron simultáneamente dos materiales de referencia certificados: IAEA 336, elementos menores y traza en liquen e IAEA V-10, elementos traza en heno en polvo. Los resultados obtenidos han mostrado buena concordancia con los reportados en el certificado, verificándose las bondades de la técnica para este tipo de matriz, como son: sensibilidad, precisión y veracidad.es_PE
dc.description.abstractThe Neutron activation analysis based in the k-subzero method (k_0 - NAA) has been used to quantify twenty six major, minor, and trace elements in coca leaves powder from different regions of Peru. Samples were irradiated at the 10 MW nuclear research reactor in the Nuclear Centre RACSO, using the pneumatic system to quantified short lived radionuclides and a core position A-9 to determined intermediate and long lived radionuclides. For quality assessment, two standard reference materials were analyzed simultaneously: IAEA 336, trace and minor elements in lichen and IAEA V-10, trace element in hay powder. The obtained results have been congruent with those reported in the certificate, confirming the goodness of the technique for this type of matrix, such as; sensitivity, precision and trueness.
dc.description.sponsorshipInstituto Peruano de Energía Nuclear
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherLima (Perú)es_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectAnálisis por activación neutrónicaes_PE
dc.subjectHoja de cocaes_PE
dc.subjectAnálisis de multi elementoses_PE
dc.subjectReactor RP-10es_PE
dc.titleAplicación de la técnica analítica de activación neutrónica en el análisis multielemental de la hoja de cocaes_PE
dc.title.alternativeMultielemental analysis of coca leaves by neutron activation analysises_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem