Medición indirecta de la actividad de iridio-192 con un teledetector versátil de 12 metros

dc.contributor.authorZapata, Luis
dc.contributor.authorArrieta, Rolando
dc.contributor.authorUrcia, Agustín
dc.contributor.authorRamos, Fernando
dc.contributor.authorOvalle, Edgar
dc.creatorArrieta, Rolando
dc.creatorOvalle, Edgar
dc.creatorRamos, Fernando
dc.creatorUrcia, Agustín
dc.creatorZapata, Luis
dc.date.accessioned2016-07-08T16:00:30Z
dc.date.available2016-07-08T16:00:30Z
dc.date.issued2008-11
dc.identifier.citationZapata L, Arrieta R, Urcia A, et al. Medición indirecta de la actividad de iridio-192 con un teledetector versátil de 12 metros. Informe Científico Tecnológico. Volumen 7 (2007) p. 138-140.es_PE
dc.identifier.issn1684-1662
dc.identifier.urihttps://hdl.handle.net/20.500.13054/552
dc.description.abstractLas tareas que se realizan en el recinto del reactor RP-10, son optimizadas constantemente con la finalidad de lograr la dosis más baja posible para el personal involucrado [1]. Una de las tareas es verificar que la actividad de las fuentes de Ir-192 irradiadas en el RP-10 cumpla con lo solicitado por la Planta de Producción de Radioisótopos (PPR). Para tal efecto, se emplea un Teledetector FAG modificado y versátil, con el fin de ubicarnos al lado opuesto de la dirección del haz primario de radiación mediante una extensión flexible de 12 metros y obtener valores indirectos de la actividad de esas fuentes de radiación.es_PE
dc.description.abstractThe tasks are performed within the perimeter of the RP-10 reactor are continuously optimized in order to achieve the lowest possible dose for the personnel involved [1]. One of those tasks is to verify that the activity of the sources of Ir-192 irradiated in the RP-10, to comply with the request of the Production of Radioisotopes Plant (PPR). To this end we use a Teledetector FAG, modified and versatile in order to locate the opposite direction of the primary beam of radiation through a flexible extension of 12 metres and get indirect values of the activity of these sources of radiation.
dc.description.sponsorshipInstituto Peruano de Energía Nuclear
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherLima (Perú)es_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectReactor RP-10es_PE
dc.subjectProducción de isótoposes_PE
dc.subjectIridio 192es_PE
dc.subjectProtección contra las radiacioneses_PE
dc.subjectDetectores de radiacioneses_PE
dc.titleMedición indirecta de la actividad de iridio-192 con un teledetector versátil de 12 metroses_PE