Determinación del voltaje de trabajo de las cadenas de arranque de los reactores nucleares RP-0 y RP-10
dc.contributor.author | Zúñiga, Agustín | |
dc.contributor.author | Veramendi, Emilio | |
dc.contributor.author | Salazar, Alberto | |
dc.creator | Veramendi, Emilio | |
dc.creator | Salazar, Alberto | |
dc.creator | Zúñiga, Agustín | |
dc.date.accessioned | 2016-11-02T16:50:31Z | |
dc.date.available | 2016-11-02T16:50:31Z | |
dc.date.issued | 2016-05 | |
dc.identifier.citation | Zúñiga A, Veramendi E, Salazar A. Determinación del voltaje de trabajo de las cadenas de arranque de los reactores nucleares RP-0 y RP-10. Informe Científico Tecnológico. 2014; 14:31-38. | es_PE |
dc.identifier.issn | 1684-1662 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13054/595 | |
dc.description.abstract | En el artículo presentamos la determinación de la curva de voltaje de las cadenas de arranque de los reactores nucleares RP-0 y RP-10, como una propuesta para obtener los voltajes de trabajo. El método consistió en variar el voltaje y registrar el contaje correspondiente. Luego, según la característica del detector se determinó la zona de mejor respuesta, así encontramos que para el reactor RP-0 su respuesta está en la región proporcional, mientras que para el reactor RP-10 su respuesta corresponde a la región de cámaras de ionización. Los valores obtenidos fueron: BF3-A3 (RP-0) 1150 voltios y para el RP-10, CF-A1 = 400 voltios, CF-A2 = 400 voltios, CF-A3 = 400 voltios. | es_PE |
dc.description.abstract | This report presents the determination of the voltage curve of the RP-0 and RP-10 nuclear reactor starting chains, as an approach for determining the working voltages. The method consisted in changing the voltage and recording the corresponding counts. Then, the area of the best response was determined according to the detector characteristics, and also was found that for the RP-0, the response was in the proportional region, meanwhile for the RP-10, the response was in the region of ionization chambers. The values obtained were: BF3-A3 (RP-0) and 1150 V for RP-10, CF-A1 = 400 V, CF-A2 = 400 V, CF-A3 = 400 V. | |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Instituto Peruano de Energía Nuclear | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.source | Instituto Peruano de Energía Nuclear | es_PE |
dc.source | Repositorio Institucional del Instituto Peruano de Energía Nuclear | es_PE |
dc.subject | Reactor RP-10 | es_PE |
dc.subject | Reactor RP-0 | es_PE |
dc.subject | Puesta en marcha de un reactor | es_PE |
dc.subject | Funcionamiento de los reactores | es_PE |
dc.subject | Cámaras de ionización | es_PE |
dc.title | Determinación del voltaje de trabajo de las cadenas de arranque de los reactores nucleares RP-0 y RP-10 | es_PE |
dc.title.alternative | Determination of the working voltage of the RP-0 and RP-10 nuclear reactors starting chains | es_PE |
dc.type | info:eu-repo/semantics/article | es_PE |
dc.publisher.country | PE | es_PE |