Mostrar el registro sencillo del ítem

Medidas antropométricas e índices nutricionales que influyen en la visualización del ganglio centinela en pacientes con cáncer de mama

dc.contributor.authorHonorio, Josseline
dc.contributor.authorLópez, Cecilia
dc.contributor.authorMorales, Rosanna
dc.contributor.authorCano, Roque
dc.creatorCano, Roque
dc.creatorLópez, Cecilia
dc.creatorHonorio, Josseline
dc.creatorMorales, Rosanna
dc.date.accessioned2017-03-31T16:21:38Z
dc.date.available2017-03-31T16:21:38Z
dc.date.issued2011-10
dc.identifier.citationHonorio J, López C, Morales R, Cano R. Medidas antropométricas e índices nutricionales que influyen en la visualización del ganglio centinela en pacientes con cáncer de mama. Informe Científico Tecnológico. 2010; 10:113-118.es_PE
dc.identifier.issn1684-1662
dc.identifier.urihttps://hdl.handle.net/20.500.13054/641
dc.description.abstractSe evaluaron cincuenta pacientes mujeres, con cáncer de mama, sometidas a linfoscintigrafía en el Centro de Medicina Nuclear IPEN-INEN. Se analizaron los siguientes factores: estatura, peso, índice de masa corporal (IMC), edad, perímetro torácico, tamaño del tumor y tiempo requerido para visualizar el ganglio centinela; para determinar su influencia en la captación y visualización del mismo, utilizando dosis estándar de radiotrazador, 5 mCi de Dextran marcado con Tc-99m. Se demostró que el tiempo de visualización del ganglio centinela se ve afectado por los siguientes factores: edad, peso, IMC, perímetro torácico y tamaño del tumor. Por lo tanto, éstas variables deben tomarse en cuenta al momento de la realización de la linfoscintigrafía para una optimización de dicho procedimiento.es_PE
dc.description.abstractFifty female patients with breast cancer were evaluated at the Nuclear Medicine Centre IPEN-INEN. These patients were previously scheduled for linfoscintigraphy. An analysis of the following factors was performed: height, weight, body mass index (BMI), age, thoracic perimeter, tumour size and time required for sentinel node identification; in order to determine their influence on uptake and visualization of the sentinel node, using a standard dose of radiopharmaceutical, 5 mCi of Dextran labelled with Technetium-99m (Tc-99m). This study demonstrates that weight, BMI, age, thoracic perimeter and tumour size affect time required for sentinel node identification. The variables previously mentioned must be considered when performing linfoscintigraphy for optimization of this procedure.
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherInstituto Peruano de Energía Nucleares_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectMedicina nucleares_PE
dc.subjectCánceres_PE
dc.subjectGlandulas mamariases_PE
dc.subjectGanglios linfáticoses_PE
dc.subjectPacienteses_PE
dc.subjectRadiografía biomédicaes_PE
dc.titleMedidas antropométricas e índices nutricionales que influyen en la visualización del ganglio centinela en pacientes con cáncer de mamaes_PE
dc.title.alternativeAnthropometric measures and nutritional indices influencing sentinel node visualization on breast cancer patientses_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem