Corrección de eficiencia por variación de geometría, empleando hojuelas de Zn como comparador en mediciones de INAA paramétrico
dc.contributor.author | Mendoza, Pablo | |
dc.contributor.author | López, Carmen | |
dc.contributor.author | Airas, Rosa | |
dc.contributor.author | Montoya, Eduardo | |
dc.creator | Montoya, Eduardo | |
dc.creator | López, Carmen | |
dc.creator | Airas, Rosa | |
dc.creator | Mendoza, Pablo | |
dc.date.accessioned | 2017-07-07T20:31:41Z | |
dc.date.available | 2017-07-07T20:31:41Z | |
dc.date.issued | 2010-11 | |
dc.identifier.citation | Mendoza P, López C, Airas Rosa, Montoya E. Corrección de eficiencia por variación de geometría, empleando hojuelas de Zn como comparador en mediciones de INAA paramétrico. Informe Científico Tecnológico. 2009; 9:54-59. | es_PE |
dc.identifier.issn | 1684-1662 | |
dc.identifier.uri | https://hdl.handle.net/20.500.13054/663 | |
dc.description.abstract | Se ha modificado la morfología del comparador de Zn, en forma de hojuela, a fin de asegurar la similitud geométrica con respecto a las muestras de matriz silícea analizadas rutinariamente por la técnica de INAA. Se ha evaluado la variación de parámetros geométricos tales como altura y ángulo sólido, encontrándose una diferencia en la eficiencia nominal (Є) para el pico de 1115.5 keV del Zn-65 del 9,1% y 6,7 % para los detectores Canberra GC70195 y GC1518, respectivamente, siendo la altura el parámetro de mayor influencia. Mediante el análisis de la muestra certificada NIST 1633b, aplicando el nuevo valor de Є calculado se ha comprobado que la eficiencia del detector GC1518 es correcta, dentro de un margen ± 5 %, a partir de 300 keV. Para el detector GC7019 se ha observado una variación sistemática entre 7 % hasta 14 % a partir de 312 keV. | es_PE |
dc.description.abstract | The foil shape of the Zn comparator has been modified, in order to ensure the geometrical similarity with the simples of siliceous matrix, which are routinely analyzed by the technique of INAA. The variation of geometrical parameters, like as height and solid angle, have been evaluated, leading nominal efficiency (Є) differences of 9.1% and 6.7 %, for the Canberra GC7019 and GC1518, detectors, for the 1115.5 keV photo peak of Zn-65, being the height the most influencing parameter. The suitability of the corrected efficiency values has been assessed by analyzing the Standard Reference material NIST 1633b. It had been found that the former efficiency curve for the detector GC1518 was right, inside a margin of ± 6 %, for E ≥ 300 keV. For the detector GC7019, it is observed a systematic difference, of about 7 % to 14 %, for E ≥ 312 keV. | |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Instituto Peruano de Energía Nuclear | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.source | Instituto Peruano de Energía Nuclear | es_PE |
dc.source | Repositorio Institucional del Instituto Peruano de Energía Nuclear | es_PE |
dc.subject | Análisis por activación neutrónica | es_PE |
dc.subject | Patrones de calibrado | es_PE |
dc.subject | Eficiencia | es_PE |
dc.subject | Control de calidad | es_PE |
dc.subject | Cinc 65 | es_PE |
dc.subject | Reactor RP-10 | es_PE |
dc.title | Corrección de eficiencia por variación de geometría, empleando hojuelas de Zn como comparador en mediciones de INAA paramétrico | es_PE |
dc.title.alternative | Correction of efficiency by geometry variation using Zn in foil as comparator in parametric INAA measurements | es_PE |
dc.type | info:eu-repo/semantics/article | es_PE |
dc.publisher.country | PE | es_PE |