Films radiocrómicos como dosímetros de rutina

dc.contributor.authorLinares, Marco
dc.contributor.authorVillanueva, Liz
dc.contributor.authorVargas, Johnny
dc.contributor.authorVivanco, Mónica
dc.contributor.authorCastro, Emma
dc.creatorLinares, Marco
dc.creatorCastro, Emma
dc.creatorVivanco, Mónica
dc.creatorVargas, Johnny
dc.creatorVillanueva, Liz
dc.date.accessioned2017-07-17T17:30:12Z
dc.date.available2017-07-17T17:30:12Z
dc.date.issued2010-11
dc.identifier.citationLinares M, Villanueva L, Vargas J, Vivanco M, Castro E, Alama D. Films radiocrómicos como dosímetros de rutina. Informe Científico Tecnológico. 2009; 9:187-191.es_PE
dc.identifier.issn1684-1662
dc.identifier.urihttps://hdl.handle.net/20.500.13054/687
dc.description.abstractLos films radiocromicos usados para hacer las películas dosimétricas tienen, en su gran mayoría, como base a un polímero de pararosanilina cianuro, el cambio de color debido a su exposición a un campo de radiación es de un claro transparente hasta tonos oscuros de púrpura con una mayor exposición a las fuentes de radiación ionizante. El cambio en la óptica de la absorbancia de este tipo de películas se puede medir en un espectrofotómetro estándar de un solo haz digital, a una longitud de onda que puede variar entre 600-675 nm durante todo el rango de uso. Este tipo de films son ideales para rayos gamma, haz de electrones, rayos X y son comúnmente usados como dosímetros de rutina en diferentes campos de aplicación de la irradiación industrial. El objetivo principal del presente trabajo es realizar los primeros estudios comparativos y de intercalibración de este dosímetro tanto en su respuesta y en las mejores condiciones de medición, comparado con un sistema dosimétrico estandarizado como el Fricke.es_PE
dc.description.abstractThe films used to make radiochromic dosimetric films, the vast majority are based on polymer pararosanilina cyanide, color change due to exposure to a radiation field, is a clear transparent to dark purple with a greater exposure to sources of ionizing radiation. The change in optical absorbance of these films can be measured in a spectrophotometer by a standard digital single beam at a wavelength that can vary from 600-675 nm over the range of use. Films of this type are ideal for gamma rays, electron beam, X-ray and are commonly used as routine dosimeters in different fields of application of the industrial irradiation. The main objective of this study is to conduct the first comparative studies or dosimeter that intercalibration of both in their response and in the best conditions of measurement, compared with a standardized system such as the Fricke dosimetric.
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherInstituto Peruano de Energía Nucleares_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectDosimetríaes_PE
dc.subjectDosímetros colorimétricoses_PE
dc.subjectCalibraciónes_PE
dc.subjectComparaciones interlaboratorioses_PE
dc.subjectIrradiación de alimentoses_PE
dc.titleFilms radiocrómicos como dosímetros de rutinaes_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.publisher.countryPEes_PE