Mostrar el registro sencillo del ítem

Determinación de cadmio mediante análisis por activación neutrónica

dc.contributor.advisorRómulo Ochoa Luna
dc.contributor.authorBedregal Salas, Patricia
dc.creatorBedregal Salas, Patricia
dc.date.accessioned2014-04-08T20:07:41Z
dc.date.available2014-04-08T20:07:41Z
dc.date.issued1996
dc.identifier.citationBedregal Salas Patricia. Determinación de cadmio mediante análisis por activación neutrónica. [Tesis para optar el Grado de Magister en Química]. Lima, Perú: Pontificia Universidad Católica del Perú, Escuela de Graduados; 1996.es_PE
dc.identifier.urihttps://hdl.handle.net/20.500.13054/70
dc.description.abstractSe ha desarrollado un método de análisis para la determinación de trazas de cadmio en muestras de alimentos y material biológico mediante la técnica de Análisis por Activación Neutrónica con separación radioquímica post-irradiación. Se irradia la muestra por 8 horas a un flujo de 10^13 n/cm^2s. Después de la digestión de la muestra con ácido nítrico y ácido perclórico en presencia de 5 mg de portador de cadmio y evaporación a sequedad, se la hace pasar por una columna de intercambio iónico cargada con resina Dowex l-X8 en forma cloruro y acondicionada con HCl 6M. El cadmio es retenido en la resina, se la lava con porciones de HCl 6M, HCl 0,25M y HCl 0,024M para eliminar interferencias de otros elementos, luego se eluye el cadmio con buffer amoníaco-cloruro de amonio y se mide la actividad inducida utilizando un detector de NaI(Tl). El método ha sido puesto a punto analizando varios materiales de referencia certificados cuyos valores de concentración de cadmio están en el rango de 0,020 a 200 partes por millón. Los resultados obtenidos coinciden con los valores certificados dentro de una discrepancia de hasta 5 % y revelan la sensibilidad y confiabilidad del método expuesto.es_PE
dc.description.abstractA radiochemical neutron activation analysis for the determination of cadmium in food and biological materials has been developed and tested. After eight hour of irradiation at 10^13 n/cm^2s thermal neutron flux and two days decay, samples and standards are treated with nitric acid, perchloric acid and 5 mg Cd (II) mixture, heating to dryness. The ashes are dissolved in HCl 6M and run through an ionic exchange column loaded with dowex 1-X8 resin pre-conditioned with HCl 6M. After it has been washed with HCl 0.25M and 0.024M for eliminating some interferences, cadmium is eluted with NH3 - NH4Cl buffer. The induced activity is measured in NaI(Tl) detector. The method has been validated by analyzing several reference materials with cadmium concentrations from 0.020 to 200 ppm range. The results agree with reference values within +-5 %.
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherLima (Perú)es_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectAnálisis por activación neutrónicaes_PE
dc.subjectCadmioes_PE
dc.subjectAnálisis químicoes_PE
dc.subjectAnálisis radioquímicoes_PE
dc.subjectMateriales biológicoses_PE
dc.titleDeterminación de cadmio mediante análisis por activación neutrónicaes_PE
dc.title.alternativeDetermination of cadmium by neutron activation analysises_PE
dc.typeinfo:eu-repo/semantics/masterThesises_PE
dc.publisher.countryPEes_PE
thesis.degree.disciplineQuímicaes_PE
thesis.degree.grantorPontifica Universidad Católica del Perú. Escula de Graduadoses_PE
thesis.degree.nameMagister en Químicaes_PE