Mostrar el registro sencillo del ítem

Comportamiento de empaques en un módulo de torre de enfriamiento para un sistema de refrigeración

dc.contributor.authorGago, Javier
dc.contributor.authorHerrera, Jamir
dc.contributor.authorPalomino, Raúl
dc.contributor.authorBoujeat, Nicolás
dc.contributor.authorHernández, Yuri
dc.contributor.authorChan, Renzo
dc.contributor.authorBaltuano, Oscar
dc.creatorBaltuano, Oscar
dc.creatorHernández, Yuri
dc.creatorChan, Renzo
dc.creatorHerrera, Jamir
dc.creatorBoujeat, Nicolás
dc.creatorGago, Javier
dc.creatorPalomino, Raúl
dc.date.accessioned2020-07-09T06:28:45Z
dc.date.available2020-07-09T06:28:45Z
dc.date.issued2019-12
dc.identifier.citationGago Javier, Herrera Jamir, Palomino Raúl, Boujeat Nicolás, Hernández Yuri, Chan Renzo, et al. Comportamiento de empaques en un módulo de torre de enfriamiento para un sistema de refrigeración. Inf. Cient. Tec. 2016; 16(2):23-30.es_PE
dc.identifier.issn2225-2029
dc.identifier.urihttps://hdl.handle.net/20.500.13054/734
dc.description.abstractEn el presente estudio se determinó la tasa de transferencia de calor de un prototipo de torre de enfriamiento utilizando dos configuraciones de empaques diferentes: la primera usando una configuración con placas ordenadas y la segunda con una distribución de placas desordenadas. El análisis de la eficiencia de ambas configuraciones se realizó mediante un estudio teórico experimental. Para ello, se construyó un prototipo de torre de enfriamiento en pequeña escala buscando replicar, hasta donde fue posible, la distribución de los componentes de una de las torres de enfriamiento del reactor RP-10. Mediante el uso de un medidor de caudal, una red de sensores de temperatura distribuidos a lo largo del circuito de agua y una fuente de calor con temperatura controlada para elevar la temperatura del agua se determinó de forma experimental que un empaque ordenado mejora la transferencia de calor del sistema en un 10.62 % con respecto a un empaque desordenado. Los resultados obtenidos, por extensión, demuestran la conveniencia de utilizar empaques en una configuración ordenada en las torres de enfriamiento del reactor RP-10 mejorando la eficiencia de las mismas.es_PE
dc.description.abstractIn the present study, the heat transfer rate of a modification tower prototype was determined using two different packaging configurations: the first one using an ordered plate configuration and the second one with a messy plate distribution. The efficiency analysis of both configurations was carried out by means of an experimental theoretical study. For this, a small-scale cooling tower prototype was built seeking to replicate, as far as possible, the distribution of the components of one of the RP-10 reactor's cooling towers. Using a flowmeter, a network of temperature sensors distributed throughout the water circuit, and a temperature controlled heat source to raise the water temperature, an orderly packaging is experimentally determined to improve the transfer of system heat by 10.62 % over a messy package. The results obtained, by extension, show the convenience of using packing in an ordered configuration in the RP-10 reactor friction towers, improving their efficiency.
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.sourceInstituto Peruano de Energía Nucleares_PE
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nucleares_PE
dc.subjectTorres de refrigeraciónes_PE
dc.subjectSistemas de refrigeraciónes_PE
dc.subjectTransferencia de calores_PE
dc.subjectModeloses_PE
dc.subjectTemperaturaes_PE
dc.subjectSensoreses_PE
dc.titleComportamiento de empaques en un módulo de torre de enfriamiento para un sistema de refrigeraciónes_PE
dc.title.alternativePackaging behavior in a cooling tower module for a cooling systemes_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.publisher.countryPEes_PE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem