Determinación del efecto de suma por coincidencia en detectores HPGe de alta eficiencia relativa
(Lima (Perú), 2007-08)
Se establece una metodología para evaluar el efecto de suma por coincidencia en detectores HPGe de alta eficiencia, relativa a mínimas distancias de medición a partir de una geometría referencial relacionando sus tasas de ...
A combined method of neutron activation analysis and radiometric measurements for U-234 and U-238 determination in soil samples of low uranium concentration
(Instituto Peruano de Energía Nuclear, 2011-10)
A method that combines the use of non-destructive neutron activation analysis and high-resolution spectrometry has been developed for determination of the activities of U-234 and U-238 in geological samples of low uranium ...
Quality assurance of analytical results in environmental samples by means of participation in intercomparison round
(Lima, 2003-07)
In developing countries, limited resources in the laboratories hinder quality assurance. One way to overcome this problem is to participate in international interlaboratory comparison rounds in order to asses the reliability ...
Factibilidad del análisis por activación neutrónica de cerámicos arqueológicos enteros: Parte 1: Precisión de resultados y seguridad radiológica del proceso
(Instituto Peruano de Energía Nuclear, 2010-04)
Se ha estudiado la factibilidad de utilizar el análisis por activación neutrónica instrumental en objetos cerámicos enteros, empleando flujos neutrónicos térmicos bajos. El estudio toma en cuenta los elementos químicos ...
The development of the k0 method in Peru: Past, present, and future perspectives
(Instituto Peruano de Energía Nuclear, 2010-11)
The k0 method was implemented at the Peruvian Institute of Nuclear Energy (IPEN), by 1993. Since the middle of 1994, almost all INAA work at IPEN is performed by the k0 method. The establishment, applications, development ...
K_0-based instrumental neutron activation analysis using MS-Excel and Canberra Genie-2000
(Instituto Peruano de Energía Nuclear, 2010-04)
We describe an application, developed in Microsoft Excel, for the complete processing of data and automated presentation of results, of k_0-based instrumental neutron activation analysis. The application makes extensive ...
Aplicación de la prueba de Youden y Steiner para la evaluación de la robustez del método de determinación multielemental en sedimento marino usando el análisis por activación neutrónica instrumental
(Lima (Perú), 2006-07)
Se presenta la aplicación de la prueba de Youden y Steiner para evaluar la robustez durante el desarrollo del método de determinación multielemental en sedimento marino, usando el análisis por activación neutrónica ...